Prod.: Engine, ver.: 6010, ID: 60000363, Wish : When PolarTrack is true, lock the cursor only to tracking angles

Wish : When PolarTrack is true, lock the cursor only to tracking angles

Article60000363
TypeWish
ProductEngine
Version6010
Date Added12/27/2007
FixedYes [1/3/2008]
Submitted byKerry Francis
Keywords

Subject

When PolarTrack is true, lock the cursor only to tracking angles

Summary

When PolarTrack is true, lock the cursor only to tracking angles (like in Ortho)

Solution

In version 6011 a new property PolarTrackLock was added in vdLayout and vdDocument object.

 

PolarTrackLock as boolean :

Get/Set the polar track lock property .If true constrains cursor movement only to the PolarTrackAngle direction.